A study on greenhouse gas emission characteristics of sow house with forced ventilation system during spring and summer
박소연* ․ 장유나** ․ 조광곤*** ․ 정민웅**** ․ 서시영***** ․ 황옥화***** ․ 박준수*****†
Park, Soyean* ・ Jang, Yu-Na** ・ Jo, Gwanggon*** ・ Jung, Min-Woong**** ・ Seo, Siyoung***** ・ Hwang, Okhwa***** and Park, Junsu*****†
This study was conducted in three similar-structured pig rooms for approximately 160 days from March 25 to August 31,
2021 to investigate greenhouse gas emissions and characteristics emitted from sow housing with forced ventilation systems. Greenhouse gas emissions and coefficients were calculated by real-time measurement of greenhouse gas (Nitrous Oxide, Methane) concentrations, ventilation rate, and inside temperature and humidity in a pig house based on the mega chamber method, which assumes a closed pig room in the form of a chamber. The average concentration of Nitrous Oxide (N2O) in each room was in the range of 0.5 to 0.6 ppm, and Methane (CH4) concentration was in the range of 28.9 to 33.5 ppm. The average N2O emissions from Rooms 1 to 3 were 4.7 ± 1.4, 4.5 ± 1.3, and 5.2 ± 1.6 mg/day · m2 · pig. In the case of CH4, average emissions were 86.0 ± 15.6, 100.2 ± 31.2, and 103.3 ± 26.7 mg/day · m2 · pig. Finally, greenhouse gas emissions from sows calculated in this study were 1.87 ± 0.6 g/year · m2 · pig (N2O) and 35.4 ± 8.8 g/year · m2 · pig (CH4). Greenhouse gas emission coefficients were calculated as carbon dioxide equivalent (CO2-eq) by applying Global Warming Potential (GWP) and were 1.38 g CO2-eq and 2.64 g CO2-eq for N2O and CH4, respectively. This suggests that the contribution of CH4 is higher than that of N2O emitted by sows. The results of this study present useful data for domestic emission coefficient research.
Greenhouse Gas Emission, Nitrous Oxide, Methane, Sow, Mechanical Ventilation
확장자는pdf1403-09.pdf
2093-5919
2586-2782
2023-06