(사)한국기후변화학회

  • 서브비주얼배너

보기페이지

The Korean Society of Climate Change Research
테들러백에서 N2O농도의 시간적 변동성 연구
Temporal Variability of N2O Gas Concentration Collected in Tedlar Bag
홍윤정 ,강성민 ,조창상 ,윤현기 ,전의찬†
Hong, Yoonjung, Kang, Seongmin, Cho, Changsang, Yun, Hyun-Ki and Jeon, Eui Chan†
In this study, the N2O, emitted from combustion facility, were analyzed by using simulated gas and field samples
to find out how long samples can be stored in Tedlar bag.
According to the results of the experiment using simulated gases (1 ppm, 5 ppm, 10 ppm) in Tedlar bag, After
144hr, N2O concentration of simulated gases changed that 1 ppm is 5.3%, 5 ppm is 12.8%, and 10ppm is 10.5%.
The higher initial concentration of simulated gas was, the larger rate of N2O concentration was changed.
In case of high concentration samples, it need to be careful when it was analyzed after 144 hr.
Stability evaluation in Tedlar bag was carried out through field samples such as combustion facility of
bituminous coal, B-C oil and LNG. The concentration rate of field samples, which is under 1 ppm of average initial
concentration, was evaluated using statistical method.
As a result, N2O concentrations were changed to field samples in the bag even when 96 hr had passed. And
after sampling, it is necessary that sample analysis should be quickly as soon as possible.
Greenhouse Gas, Nitrous Oxide, Tedlar Bag, Temporal Variability
확장자는pdf0901-05.pdf
2093-5919
2586-2782
2018-03